Description
The Domin S10 Pro is the most efficient direct-drive high-flow servo valve in its class, replacing bulky conventional servo valves with a significantly more compact and lighter solution. With a nominal flow rate of up to 250 l/min and a high control bandwidth, it is particularly suitable for energy-intensive applications such as hydraulic presses, turbine test benches, railway technology and large-scale test systems. The integrated on-board electronics with spool position feedback eliminate the need for an external amplifier.
Technical highlights
- Direct-drive servo valve (rotary-linear), size NG10
- Integrated on-board electronics with slide position feedback – no external amplifier required
- Response time under 7 ms, frequency response above 140 Hz (–90° phase, up to 170 l/min)
- Hysteresis less than 0.2 per cent, threshold less than 0.1 per cent
- Nominal flow rate 50 to 250 l/min (rated at 70 bar ΔP), maximum flow rate up to 475 l/min
- Maximum operating pressure 350 bar (P, A, B) / 250 bar (T)
- Chip shear force in excess of 700 N – exceptional tolerance to contamination
- Leakage of less than 1 l/min (50–170 l/min) or less than 3 l/min (170–250 l/min) at 100 bar
- Supply voltage 22–30 V DC, peak current 8 A (fuse rating 10 AT)
- Vibration resistance: 30 g (all axes); shock resistance: 50 g
- ISO 4401-05-04 mounting interface, tightening torque 13 Nm
- Valve mass: 4.0 kg
Order code: S10 Pro – [1] – [2] – [3] – [4] – [5] – [6] – [7] – [8] – [Custom ID]
Example: S10 Pro – 100 – A – A – C – E – N – R – N
= 100 l/min · Axis Cut · ±10 V · centre position · 6+PE round plug · no enable · standard oil · nitrile
| Position | Description | Options |
|---|---|---|
| [1] | Nominal flow rate | 50 to 250 l/min (any value, rated at 35 bar ΔP per control edge; 250 l/min available only with Axis Cut) – suffix R for reversed A/B connections (e.g. 250R) |
| [2] | Valve overlap | A – Axis Cut (0% overlap, 100% flow gradient, linearised) D – Deadband (±10% deadband, no flow in the zero range) O – Overlap (±3% overlap, 50% gain at the centre) X – Special version available on request |
| [3] | Control signal | A – ±10 V | B – ±20 mA | C – 4–20 mA | D – ±5 V | E – ±5 mA | F – ±10 mA | G – ±50 mA | H – ±40 mA | I – ±25 mA | X – Special Combined input/output possible (e.g. AC = ±10 V input, 4–20 mA output) |
| [4] | De-energised position | C – Centre position (valve returns passively to the neutral position) X – Special version available on request |
| [5] | Electrical connector | E – 6+PE circular connector, EN 175201-804 / MIL 5015, housing size 14 (A = +24 V / B = 0 V / C = 0 V reference or enable output / D = input+ / E = input− / F = output signal / G = earth) E4 – 4-pin round plug, EN 175201-804 / MIL 5015, housing size 14 (A = +24 V / B = Input+ / C = Input− / D = 0 V) X – Special version available on request |
| [6] | Enable function | N – No enable function Y – Enable mode via voltage input (Drive ON: 9–30 V / Drive OFF: 0–5 V / input impedance approx. 15 kΩ; only with connector E) |
| [7] | Hydraulic fluid | R – Hydraulic oil in accordance with DIN 51524, filtered to ISO 4406 18/16/13 X – Special version available on request |
| [8] | Seal material | N – Nitrile NBR (Shore 90) – standard for mineral oils V – Viton FKM (Shore 85) – enhanced resistance to high temperatures and chemicals X – Special version available on request |
Data sheet: https://domin.com/datasheet/s10-pro