{"id":16291,"date":"2023-04-28T15:07:08","date_gmt":"2023-04-28T13:07:08","guid":{"rendered":"https:\/\/schuhmacher-tech.de\/products\/oil-diagnosis-with-portable-oil-lab\/"},"modified":"2023-11-27T15:23:24","modified_gmt":"2023-11-27T14:23:24","slug":"oil-diagnosis-with-portable-oil-lab","status":"publish","type":"page","link":"https:\/\/schuhmacher-tech.de\/en\/products\/oil-diagnosis-with-portable-oil-lab\/","title":{"rendered":"Oil diagnosis with Portable Oil Lab"},"content":{"rendered":"<p>[vc_row][vc_column][ultimate_heading main_heading=&#8221;Oil diagnosis with Portable Oil Lab:&#8221; heading_tag=&#8221;h1&#8243; alignment=&#8221;left&#8221;]<\/p>\n<h2 style=\"text-align: left;\"><strong>The ideal companion for fluid analysis for system service<\/strong><\/h2>\n<p>[\/ultimate_heading][vc_column_text]<\/p>\n<h3><\/h3>\n<h3><strong>Why mobile oil diagnosis<\/strong><\/h3>\n<p>Knowing the current condition of the fluid is very important for operators of production plants and units, as a machine failure is associated with long downtimes and high downtime costs. In order to detect changes in the hydraulic oil and contamination at an early stage, the operators take a sample at set intervals and send it to an oil laboratory. This process has become established across the board in recent years and continues to be a very good solution for detecting damage at an early stage.<\/p>\n<p>However, this process also harbors some risks. Often the wrong or dirty containers are used for sampling, which means that the analysis cannot be carried out or the laboratory result is incorrect. Just as important as a suitable container is the cleanliness of the environment in which the sample is taken. If the sample is taken in humid or dusty ambient air, this can already have an effect on the water content of the oil or on particle contamination.<\/p>\n<p>Another disadvantage of classic oil analysis is time. It can take several days from the time the oil is extracted until the report is analyzed. As a result, a low-cost error can quickly develop into massive and cost-intensive damage.<\/p>\n<p>ARGO-HYTOS GmbH has recognized this problem and developed a portable oil laboratory especially for such service operations.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-59840429555dc68ebf1f4ee42d912728.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-59840429555dc68ebf1f4ee42d912728.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-59840429555dc68ebf1f4ee42d912728 .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-59840429555dc68ebf1f4ee42d912728 .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-59840429555dc68ebf1f4ee42d912728 alignnone enable-bg-rollover dt-icon-bg-off\" style=\"margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; width:500px;\"><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img fetchpriority=\"high\" decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%20500%20459&#39;%2F%3E\" data-src=\"https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/Argo_Hytos_Portable_Oil_Lab-500x459.jpg\" data-srcset=\"https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/Argo_Hytos_Portable_Oil_Lab-500x459.jpg 500w, https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/Argo_Hytos_Portable_Oil_Lab.jpg 956w\" loading=\"eager\" sizes=\"(max-width: 500px) 100vw, 500px\" width=\"500\" height=\"459\"  data-dt-location=\"https:\/\/schuhmacher-tech.de\/en\/produkte\/argo_hytos_portable_oil_lab\/\" style=\"--ratio: 500 \/ 459;\" alt=\"Argo_Hytos_Portable_Oil_Lab\" \/><\/div><\/div><\/div><style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">#default-btn-0acee865f5fa9c914e4736c7abfc9692.ico-right-side > i {\n  margin-right: 0px;\n  margin-left: 8px;\n}\n#default-btn-0acee865f5fa9c914e4736c7abfc9692 > i {\n  margin-right: 8px;\n}\n<\/style><div class=\"btn-align-center\"><a href=\"url:http%3A%2F%2Fschuhmacher-tech.de%2Fwp-content%2Fuploads%2F2023%2F05%2FDatenblatt_OPCom_Portable_Oil_Lab_100.60_DE_US_0221.pdf\" class=\"default-btn-shortcode dt-btn dt-btn-m link-hover-off\" id=\"default-btn-0acee865f5fa9c914e4736c7abfc9692\"><span>data sheet<\/span><\/a><\/div>[vc_column_text]&nbsp;<\/p>\n<p style=\"text-align: center;\">Figure 1: ARGO-HYTOS Portable Oil Lab<\/p>\n<p>&nbsp;<\/p>\n<h4><strong>Portable Oil Lab<\/strong><\/h4>\n<p>The Portable Oil Lab was specially developed for service and maintenance staff who have to service several systems every day and its compact and robust design makes it the perfect companion for everyday work.<\/p>\n<p>In order to survive the daily work routine, a rechargeable battery is installed inside the device, which supplies the device with energy for approx. 8 hours in pump mode. If the device is installed directly in the high-pressure line (max. 320 bar), the battery can supply the device with energy for more than 24 hours.<\/p>\n<p>The user has two options for oil removal:<\/p>\n<ol>\n<li>Suction of the oil using the integrated pump. The built-in pump can pump viscosities of up to approx. 400 cSt. This means that gear oil is also no problem for the Portable Oil Lab.<\/li>\n<li>The device can also be integrated directly into the high-pressure line (max. 320 bar) using the integrated high-pressure adapter. To avoid confusion between the low-pressure and high-pressure connections, ARGO-HYTOS has deliberately opted for two different connections.<\/li>\n<\/ol>\n<p>The OPCom 2 particle monitor is used to measure particle contamination.[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1683009493450{margin-top: 30px !important;}&#8221;][vc_column]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-c17ee31111f720e69a8122d37a51eb5f.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-c17ee31111f720e69a8122d37a51eb5f.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-c17ee31111f720e69a8122d37a51eb5f .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-c17ee31111f720e69a8122d37a51eb5f .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-c17ee31111f720e69a8122d37a51eb5f alignnone enable-bg-rollover dt-icon-bg-off\" ><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%20400%20288&#39;%2F%3E\" data-src=\"https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/Partikelmonitor_OPCom2-1-400x288.png\" data-srcset=\"https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/Partikelmonitor_OPCom2-1-400x288.png 400w, https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/Partikelmonitor_OPCom2-1.png 750w\" loading=\"eager\" sizes=\"(max-width: 400px) 100vw, 400px\" width=\"400\" height=\"288\"  data-dt-location=\"https:\/\/schuhmacher-tech.de\/en\/produkte\/partikelmonitor_opcom2-2\/\" style=\"--ratio: 400 \/ 288;\" alt=\"Partikelmonitor_OPCom2\" \/><\/div><\/div><\/div>[vc_column_text]<\/p>\n<p style=\"text-align: center;\">Figure 2: Particel monitor OPCom 2<\/p>\n<p>&nbsp;<\/p>\n<p>Particle sizes of 4\u00b5m\/6\u00b5m\/14\u00b5m and 21 \u00b5m can be measured with this sensor. The measured particle class can be displayed in ISO 4406, NAS, SAE or Ghost.<\/p>\n<p>In contrast to other devices available on the market, the condition sensor from ARGO-HYTOS is installed inside the Portable Oil Lab (Figure 3)[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">.shortcode-single-image-wrap.shortcode-single-image-55e937163cbade6fad567d686b5409ed.enable-bg-rollover .rollover i,\n.shortcode-single-image-wrap.shortcode-single-image-55e937163cbade6fad567d686b5409ed.enable-bg-rollover .rollover-video i {\n  background: -webkit-linear-gradient();\n  background: linear-gradient();\n}\n.shortcode-single-image-wrap.shortcode-single-image-55e937163cbade6fad567d686b5409ed .rollover-icon {\n  font-size: 32px;\n  color: #ffffff;\n  min-width: 44px;\n  min-height: 44px;\n  line-height: 44px;\n  border-radius: 100px;\n  border-style: solid;\n  border-width: 0px;\n}\n.dt-icon-bg-on.shortcode-single-image-wrap.shortcode-single-image-55e937163cbade6fad567d686b5409ed .rollover-icon {\n  background: rgba(255,255,255,0.3);\n  box-shadow: none;\n}\n<\/style><div class=\"shortcode-single-image-wrap shortcode-single-image-55e937163cbade6fad567d686b5409ed alignnone enable-bg-rollover dt-icon-bg-off\" ><div class=\"shortcode-single-image\"><div class=\"fancy-media-wrap  layzr-bg\" style=\"\"><img decoding=\"async\" class=\"preload-me lazy-load aspect\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D&#39;http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg&#39;%20viewBox%3D&#39;0%200%20181%20279&#39;%2F%3E\" data-src=\"https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/LubCos_H2OII.png\" data-srcset=\"https:\/\/schuhmacher-tech.de\/wp-content\/uploads\/2023\/04\/LubCos_H2OII.png 181w\" loading=\"eager\" sizes=\"(max-width: 181px) 100vw, 181px\" width=\"181\" height=\"279\"  data-dt-location=\"https:\/\/schuhmacher-tech.de\/en\/produkte\/lubcos_h2oii\/\" style=\"--ratio: 181 \/ 279;\" alt=\"LubCos_H2O+II\" \/><\/div><\/div><\/div>[vc_column_text]<\/p>\n<p style=\"text-align: center;\">Figure 3: LubCos H2O+II<\/p>\n<p>&nbsp;<\/p>\n<p>In addition to the rel. humidity (0&#8230;100%) and the permittivity P, the conductivity C of the oil can also be measured.<\/p>\n<p>Each type of oil has a characteristic permittivity, it is the fingerprint of the oil, so to speak. The Portable Oil Lab therefore makes it possible to detect mixtures of different oils or filling with the wrong oil.<\/p>\n<p>The measured values of the device are saved in the internal memory and can be transferred to a PC for further processing in a database after a successful service.<\/p>\n<p>The device is equipped with an integrated printer. Measured results can be printed out directly on site at the system and discussed with the user or customer.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text css=&#8221;.vc_custom_1683009592198{margin-top: 100px !important;}&#8221;]<\/p>\n<h5><strong>Customer Benefits<\/strong><\/h5>\n<ul>\n<li>Quick and easy operation via the integrated buttons<\/li>\n<li>Quick detection of error causes through direct measurement on the machine<\/li>\n<li>Integrated printer for immediate printing of results<\/li>\n<li>Robust and compact design<\/li>\n<li>Reduction of downtimes and costs through early detection of changes in the hydraulic oil<\/li>\n<li>Avoidance of possible incorrect laboratory results by using the Portable Oil Lab<\/li>\n<li>Saving time and money through quick fluid analysis on site<\/li>\n<li>Reduced environmental impact by avoiding unnecessary oil changes due to incorrect or faulty results<\/li>\n<li>Extending the service life of hydraulic systems<\/li>\n<li>Preventing failures and protecting hydraulic components<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column css=&#8221;.vc_custom_1690542873936{margin-top: 100px !important;margin-bottom: 50px !important;}&#8221;][ultimate_heading main_heading=&#8221;Are you looking for off-line filters? We will be happy to advise you!&#8221; heading_tag=&#8221;h3&#8243;]Contact us <a href=\"tel:%20+49%207424%209495%20663\">by phone<\/a>, <a href=\"mailto:lars.benk@schuhmacher-tech.de\">e-mail<\/a> or via our <a href=\"https:\/\/schuhmacher-tech.de\/en\/contact-us\/\">contact form<\/a>. We can help you find the perfect solution for off-line filtration.[\/ultimate_heading][\/vc_column][\/vc_row][vc_row][vc_column]<style type=\"text\/css\" data-type=\"the7_shortcodes-inline-css\">#default-btn-bbaf5f7b7bea1e8df73c6b0420bd9275.ico-right-side > i {\n  margin-right: 0px;\n  margin-left: 8px;\n}\n#default-btn-bbaf5f7b7bea1e8df73c6b0420bd9275 > i {\n  margin-right: 8px;\n}\n<\/style><div class=\"btn-align-center\"><a href=\"url:http%3A%2F%2Fschuhmacher-tech.de%2Fen%2Fcontact-us%2F\" class=\"default-btn-shortcode dt-btn dt-btn-m link-hover-off\" id=\"default-btn-bbaf5f7b7bea1e8df73c6b0420bd9275\"><span>Go directly to the contact form!<\/span><\/a><\/div>[\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][ultimate_heading main_heading=&#8221;Oil diagnosis with Portable Oil Lab:&#8221; heading_tag=&#8221;h1&#8243; alignment=&#8221;left&#8221;] The ideal companion for fluid analysis for system service [\/ultimate_heading][vc_column_text] Why mobile oil diagnosis Knowing the current condition of the fluid is very important for operators of production plants and units, as a machine failure is associated with long downtimes and high downtime costs. In order&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":16285,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-16291","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/pages\/16291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/comments?post=16291"}],"version-history":[{"count":0,"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/pages\/16291\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/pages\/16285"}],"wp:attachment":[{"href":"https:\/\/schuhmacher-tech.de\/en\/wp-json\/wp\/v2\/media?parent=16291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}